Zero-Profile Anterior Cervical Intervertebral Locking Plate and Cage Combination System
The Cervical Interboday Cage for the treatment of ruptured and herniated discs, degenerative disc disease and spinal instability, pseudarthrosis or failed spondylodesis.
PEEK-OPTIMA® material is biocompatible and much closer to that of spongy bone, consequently minimizing the risk of systemic uptake and local inflammatory reactions.
Anterior Cervical Spine Locking Plate System IV with its low profile design and special locking mechanism can help to stabilize the cervical spine from C2 to C7
The Anterior Cervical Spine Plate Ⅰ is designed with graft visibility window, adjusting angle, anti-migration system, color-coded, self-drilling screws, low profile to provide treatments for degenerative disc disease, trauma, tumors, deformity (defined as kyphosis, lordosis, or scoliosis), pseudarthrosis, failed previous fusions and so on.
The Anterior Cervical Spine Plate Ⅲ is designed with double and single line, bending zones, maximized visibility window, locking structure, low profile, variable and fixed angle screws, anti-slippage teeth to provide solutions fordegenerative disc disease, trauma,tumors,deformity (defined as kyphosis, lordosis, or scoliosis),pseudarthrosis, failed previous fusions and so on.
The design of Delta Anterior Cervical Plate and Cage Combination System has three-screw plate for multi-planar stability, and Delta Guide with its fixed angle screw insertion which ensures optimal alignment for plate, cage and screw. In the meantime, Delta Anterior Cervical Plate and Cage Combination System can be used for degenerative disc disease, trauma, tumor, deformity (defined as kyphosis, lordosis, or scoliosis), pseudarthrosis, and failed previous fusions and so on.
Proximal lateral tibial osteotomy LCP is intended to treat the unicompartmental medial or lateral knee osteoarthritis with malalignment of the proximal tibia and idiopathic or posttraumatic varus or valgus deformity of the proximal tibia.
VAL Proximal Humeral Locking Plate is used for fractures of proximal humerus including complex fracture, fracture dislocation, bone nonunion and osteotomy.
I Tenting Screw
Indications
Used when it needs to be vertical/horizontal to GBR.
Material: Titanium alloy
Features
Make room for bone graft.
Easy implantation with self-drilling design of the tip.
Hole-drilling with limit drill before implantation.
Specifications
Tenting Screw, φ1.6×10mm
Tenting Screw, φ1.6×7mm
II Tenting Screw
Indications
maintain the osteogenic space and fifix the barrier membrane
Features
Provide stable support space for GBR.
Fix the barrier membrane with its screw cap design effectively.
Simplified surgery, easy operation.
Specifications
Tenting Screw φ1.4×3mm
Tenting Screw φ1.6×11mm